Class 105 Paper-Covered Bare Rectangular Copper Wire

Thermal Class:105
Springback: Not less than 5.5º
Insulation materials:rope paper, kraft paper, or both

Class 105 Paper-Covered Bare Rectangular Copper Wire

Class 105 Paper-Covered Bare Rectangular Copper Wire is a type of magnet wire used in electrical applications. This wire consists of a rectangular copper conductor that is bare (not insulated) and is coated with a layer of paper insulation.

Insulating Material:

The insulating material shall be rope paper, kraft paper, or both. The paper covering shall be one or more tape layers wrapped firmly, closely, evenly, and continuously around the wire.

Thermal Class: 105 impregnated or in oil. The thermal class of fibrous-covered or paper tape–wrapped wire shall be based on experience.

Dimensions:

Rectangular Wire:

Bare wire radii

 Bare wire radii /mm WidthThickness
 Mini: 2.032-16.370Nom: 2.057-16.535Max:2.083-16.701Mini: 0.991-7.267Nom: 1.016-7.341Max:1.041-7.414

For covering, see the Table for wire having two or three layers (N) and tape thickness of 0.002 or 0.003 in. (0.051 or 0.076 mm).

Increase in Dimensions of Rectangular Wire Due to Tape Covering

 Nt = 0.0015 in (0.038 mm)t = 0.002 in (.051 mm)t = 0.003 in (.076 mm)
MinimumMaximumMinimumMaximumMinimumMaximum
InchesmmInchesmmInchesmmInchesmmInchesmmInchesmm
20.0050.1270.0090.2290.0070.1780.0120.3050.0100.2540.0180.457
30.0080.2030.0120.3050.0100.2540.0160.4060.0150.3810.0240.610

The increase in dimensions for coverings having other layers or other tape thickness shall be in accordance with the next table.

Fibrous coverings shall be wrapped firmly, closely, evenly, and continuously around the wire. When

more than one tape covering is applied, adjacent tapes shall be permitted to be wound in the same or in opposite directions. The relation of the percentage of overlap of the tape to the number of layers of tape is shown as follows:

Wrap DescriptionNumber of Tape Layers (N)
Percentage of Overlap
0n
Greater than 0 to 251.33n
Greater than 25 to 331.5n
Greater than 33 to 401.67n
Greater than 40 to 502n
Greater than 50 to 673n
Greater than 67 to 754n

Elongation: Not less than 32% for a conductor thickness of 0.049 in. (1.25 mm) and greater, or 30% for a conductor thickness less than 0.049 in. (1.25 mm)

Adherence And Flexibility: Covering shall not loosen appreciably nor open sufficiently to expose the bare wire after bending around a mandrel having a dimension six times the thickness of the bare wire.

Springback: Not greater than 5.5º

This type of wire is designed to meet specific electrical and mechanical requirements and is manufactured to industry standards to ensure reliability and performance in various applications.