Class 180Glass Fiber Covered High-Temperature Square Copper Magnet Wire 

Insulation materials Glass Fiber Film(Organic Varnish Treated)
Thermal Class 180
Conductor Copper
Insulation thickness Single/Heavy
Certificate MW-52C
Class 180Glass Fiber Covered High-Temperature Square Copper Magnet Wire 

Wire Types

Class 180 Glass Fiber Covered High-Temperature Organic Varnish Treated Bare Square Copper Magnet Wire

Class 180 Glass Fiber Covered High-Temperature Organic Varnish Treated Film-Insulated Square Copper Magnet Wire

Class 180 Glass Fiber Covered Bare Square Copper Magnet Wire

Class 180 Glass Fiber Covered Film-Insulated Square Copper Magnet Wire

Class 180 Glass Fiber Covered High-Temperature Square Copper Magnet Wire

Insulating Material

The glass fiber shall be electrical-grade continuous-filament glass yarn. If underlying film insulation is used, it shall have at least a class 155 rating and comply with the applicable specification of Glass Fiber Covered High-Temperature Square Copper Magnet Wire. The glass fiber covering shall be wrapped firmly, closely, evenly, and continuously around the wire. The glass fiber covering shall be treated with a high- temperature non-silicone insulating varnish.

Thermal Class

180

Conductor

Square Copper Magnet Wire

Dimensions

Table1 Dimensions of Square Bare Wire

AWGMinimumNominalMaximumNominal Corner Radius ±25%
1/08.1718.2528.3341.00
17.2757.3487.4221.00
26.4776.5436.6091.00
35.7685.8275.8851.00
45.1385.1895.2401.00
54.5754.6204.6661.00
64.0744.1154.1550.80
73.6303.6653.7010.80
83.2313.2643.2970.80
92.8782.9062.9340.67
102.5632.5882.6140.67
112.2782.3042.3290.50
122.0272.0522.0780.50
131.8031.8291.8540.40
141.6031.6281.6540.40

Table2  (mm) Heavy and Quad Film-Insulated Square Magnet Wire Increase in Dimensions Due to Film Coating

Square AWGSizeBare Wire DimensionsRadii (±25%)NominalHeavyQuadruple
Minimum IncreaseMaximum OverallMinimum IncreaseMaximum Overall
MinimumNominalMaximum
17.2757.3487.4221.000.0807.5490.1277.600
26.4776.5436.6091.000.0806.7360.1276.787
35.7685.8275.8851.000.0806.0120.1276.063
45.1385.1895.2401.000.0805.3670.1275.418
54.5754.6204.6661.000.0804.7930.1274.844
64.0744.1154.1550.800.0804.2820.1274.333
73.6303.6653.7010.800.0803.8280.1273.879
83.2313.2643.2970.800.0803.4240.1273.475
92.8782.9062.9340.670.0803.0610.1273.112
102.5632.5882.6140.670.0802.7410.1272.791
112.2782.3042.3290.500.0802.4560.1272.507
122.0272.0522.0780.500.0802.2050.1272.256
131.8031.8291.8540.400.0801.9810.1272.032
141.6031.6281.6540.400.0801.7810.1271.831

Table3 (mm) Single Glass Fiber Covered, Heavy Film-Insulated Square Copper Magnet Wire-Minimum Increase and Maximum Overall Dimensions Due to Insulation

 AWGSize Bare Wire Dimensions Radii (±25%) NominalHeavy Film-Coated Single GlassCovered
Minimum IncreaseMaximum Overall
MinimumNominalMaximum
1/08.1718.2528.3341.000.2798.738
17.2757.3487.4221.000.2547.798
26.4776.5436.6091.000.2546.985
35.7685.8275.8851.000.2546.274
45.1385.1895.2401.000.2545.613
54.5754.6204.6661.000.2295.029
64.0744.1154.1550.800.2294.521
73.6303.6653.7010.800.2294.039
83.2313.2643.2970.800.2293.632
92.8782.9062.9340.670.2293.277
102.5632.5882.6140.670.2292.946
112.2782.3042.3290.500.2032.642
122.0272.0522.0780.500.2032.388
131.8031.8291.8540.400.2032.159
141.6031.6281.6540.400.2031.956

Table4 (mm) Double Glass Fiber Covered, Bare or Heavy Film-Insulated Square Copper Magnet Wire-Minimum Increase and Maximum Overall Dimensions Due to Insulation

  Square AWGSize Bare Wire Dimensions Nominal Radii ±25%BareDouble Glass CoveredHeavy Film-Insulated Double Glass Covered
Minimum IncreaseMaximum OverallMinimum Increase*Maximum Overall
MinNominalMax
mmmmmmmmmmmmmmmm
1/08.1768.2528.3291.000.3308.7880.4068.915
17.2757.3487.4221.000.3057.8490.3817.976
26.4776.5436.6091.000.3057.0360.3817.163
35.7685.8275.8851.000.2796.2990.3566.426
45.1385.1895.2401.000.2795.6390.3565.766
54.5754.6204.6661.000.2795.0550.3565.182
64.0744.1154.1550.800.2794.5470.3564.674
73.6303.6653.7010.800.2544.0640.3304.191
83.2313.2643.2970.800.2543.6580.3303.785
92.8782.9062.9340.670.2293.2770.3053.404
102.5632.5882.6140.670.2292.9460.3053.073
112.2782.3042.3290.500.2032.6420.2792.769
122.0272.0522.0780.500.2032.3880.2792.515
131.8031.8291.8540.400.2032.1590.2792.286
141.6031.6281.6540.400.2031.9560.2792.083

General Requirements

PropertiesRequirement
DIMENSIONSSquare Wire:
Radii in accordance with Table1
Thickness and width tolerances in accordance with Table2
Dimensions and increase in thickness in accordance with:
Single: Table3
Double: Table4
ADHERENCE AND FLEXIBILITYSingle or Double with underlying film: no cracks visible in the film insulation after 20% elongation. Examine with normal vision and without removing the glass fiber covering. 

Double without underlying film: not less than 75 V/mil (2950 V/mm) of minimum thickness of the polyester glass fiber covering on one side
ELONGATIONNot less than 32% for a thickness of 0.049 in. (1.25 mm) and greater, or 30% for a thickness of less than 0.049 in. (1.25 mm)
SPRINGBACKGlass fiber covered bare: not greater than 5º
Glass fiber covered Heavy film-insulated: not greater than 5.5º
DIELECTRIC BREAKDOWNNot less than 90 V/mil (3543 V/mm) of the minimum thickness of the glass fiber covering on one side plus the minimum breakdown given in Table5 for the film-insulated wire, if applicable
NOTE—The minimum thickness of the glass fiber covering is 35% of the maxi-mum increase in dimensions calculated from: Single: Square: Table3
Double: Square without underlying film: Table4

Table5 Dielectric Breakdown, Film-Insulated Square Magnet Wire

Film InsulationMinimum Breakdown Voltage
Any Three of Four ValuesFourth Value
Heavy1500500
Quad2500900