Class 200 Polyester Overcoated with Polyamideimide Film-Insulated Round Copper Magnet Wire for Hermetic Applications

Insulation thickness:Heavy and Quad
Dimensions:Heavy 0.307mm-1.732mm;Quad 0.351mm-1.814mm
Thermal Class:200
Certificate:MW 73-C

Class 200 Polyester Overcoated with Polyamideimide Film-Insulated Round Copper Magnet Wire for Hermetic Applications

Class 200 Polyester Overcoated with Polyamideimide Film-Insulated Round Copper Magnet Wire for Hermetic Applications. This specific wire is particularly designed for demanding applications such as those in hermetic motors and compressors.

Types

Polyester Overcoated with Polyamideimide;

Polyester (lmide) Overcoated with Polyamideimide;

Polyester (Amide) Overcoated with Polyamideimide

Specifications

Insulation materialsPolyester Overcoated with Polyamideimide;Polyester (lmide) Overcoated with Polyamideimide;Polyester (Amide) Overcoated with Polyamideimide
DimensionsHeavy 14-30 AWG in accordance with 0.307mm-1.732mm and Quad 14-30 AWG in accordance with 0.351mm-1.814mm
Insulation thicknessHeavy and Quad
Thermal Class200
CertificateMW 73-C

Properties

Adherence and flexibilityNo cracks visible in the film coating
ElongationNot less than the value in 5-28
Heat shockNo cracks visible in the film coating after conditioning at 220ºC
SpringbackNot greater than the value in Heavy 42-66;Quad 46-70
Dielectric breakdown14-23.5 AWG: not less than the value in Heavy 4440-5690;Quad 7720-9900
24-30 AWG: not less than the value in Heavy 3800-4380;Quad 6600-7620
ContinuityMax number of discontinuities in accordance with Heavy 500-1500;Quad 1000-2500
Thermoplastic flowMedian not less than 300ºC

Periodic conformance test

Thermoplastic flowMedian not less than 300ºC
SolubilitySpecimens immersed in xylene and 50/50 xylene/butyl Cellosolve shall not soften sufficiently to expose the bare conductor
Dielectric breakdown at rated temperatureAverage not less than 75% of the value required at room temperature
Refrigerant R22 extraction14-24 AWG: not greater than 0.25% of weight of film insulation
Dielectric breakdown after R22 conditioners14-24 AWG: average not less than the value in Heavy 4380-5690;Quad 7620-9900

Scrape resistance

Lowest grams-to-fail load for any one of three tests, and the average of the three tests shall not be less than the values in the following table:

Wire Size Range AWGMandrel Diameter (inches)Maximum Winding Force (grams)Load on Coil During Bonding (grams)Peel Strength at Room Temperature (grams)Peel Strength at Elevated Temperature (grams)
14-14.50.551200675850350
15-15.50.471200500650250
16-16.50.431200450600225
17-17.50.391200400500200
18-18.50.35500350425175
19-19.50.31500250350125
20-20.50.28500200285100
21-21.50.2450017522590
22-23.50.2020012516065
24-25.50.162007511035
26-27.50.1280507025
28-31.50.0880353520
32-33.50.0430252510
34-37.50.0412151210
38-40.50.045585