Class 120 Polyvinyl Acetal Film Insulated Round Copper Magnet Wire

Dimensions:

Single 14–56 AWG; Heavy 4–50 AWG; Triple 14–30 AWG

single:14-56AWG

minimum increase: 0.0013mm-0.041mm

maximum overall: 0.0165mm-1.692mm

heavy: 4-50AWG

minimum increase: 0.0051mm-0.094mm

maximum overall: 0.0356mm-5.329mm

triple: 14-30 AWG

minimum increase: 0.015mm-0.069mm

maximum overall: 0.074mm-0.538mm

Class 120 Polyvinyl Acetal Film Insulated Round Copper Magnet Wire

Class 120 Polyvinyl Acetal can withstand temperatures up to 120°C with a specific thermal class of insulation material.

Insulating Material: The coating is based on a blend of polyvinyl acetal and phenolic resins.

Dimensions:

Single 14–56 AWG; Heavy 4–50 AWG; Triple 14–30 AWG

single:14-56AWG

minimum increase: 0.0013mm-0.041mm

maximum overall: 0.0165mm-1.692mm

heavy: 4-50AWG

minimum increase: 0.0051mm-0.094mm

maximum overall: 0.0356mm-5.329mm

triple: 14-30 AWG

minimum increase: 0.015mm-0.069mm

maximum overall: 0.074mm-0.538mm

Adherence And Flexibility: No cracks visible in the film coating

Elongation: Not less than 5 %

Heat Shock: No cracks visible in the film coating after conditioning at 175°C

Springback: 14–30 AWG: Not greater than 42°

4–13 AWG: Not greater than 5°

Dielectric Breakdown:

4-9.5 AWG: not less than 1870V

10-23.5 AWG: not less than 2470V

24-37 AWG: not less than 1220V

38-56 AWG: not less than 80V

Completeness Of Cure: No swelling or blistering visible in the film coating

Periodic Conformance Tests:

Thermoplastic Flow: Median not less than 180°C

Solubility: Specimens immersed in xylene shall not soften sufficiently to expose the bare

Conductor

Dielectric Breakdown At Rated Temperature: Average less than 75% of the value required at room temperature

Transformer Oil Resistance: 18 AWG Heavy film insulated wire shall not average less than 5700 volts